From fine strands to armored lines — high-performance copper conductors for safe energy flow.
LSHF insulated cables (with or without outer sheath) with flame retardant and low smoke haloegen free properties, used for indoor electrical appliances. The cables are designed to be installed in conduits (heavy-duty, anti-leakage) as fixed on/in the walls, ceillings or floors, embedded in the walls, ceillings or floors or buried underground.
AS/NZS 5000.1; AS/NZS 5000.2; AS/NZS 3808; AS/NZS 1125; IEC 61034-2; IEC 60754-1,2; IEC 60332-1. Maximum conductor temperature for normal operation is 90°C. Maximum conductor temperature for short-circuit (5s maximum duration) is 160°C. LSHF insulation and sheath: flame retardant and low smoke haloegen free properties. The maximum permission load current is higher than that of regular PVC wire.
VCmo-LF wires are designed by use of lead-free (LF) material, high
flexibility, easy-to-tear outer sheath, max conductor temperature for
normal operation is 90°C, used for indoor electrical appliances. The
cables are designed to be installed in conduits (heavy-duty, anti-leakage)
at installation positions such as the walls, ceillings or floors.
Made in accordance to AS/NZS 5000.2; AS/NZS 3808; AS/NZS 1125. Maximum
conductor temperature for normal operation is 90°C. Maximum conductor
temperature for short-circuit (5s maximum duration) is 160°C. Maximum
permission load current is higher than that of regular PVC wire. Heat
resistant lead-free (LF) insulation and sheath is environment friendly.
PVC sheath type 3V90 (easy-tear properties).
Cables are designed for use lead-free (LF) materials, high flexible,
safe operation up to 105°C (HR). The cables ideal for internal use in
switchboards, electrical appliances in households, televisions and
control desks, are also suitable as connection wire in equipments, for
laying in protective and flexible tubes, for engines and transformators.
Made in accordance to TCVN 6612 / IEC 60228; TCVN 5935-1 /IEC 60502-1;
UL 758. Min. bending radius: 6 x D (D: overall diameter). Rated voltage
U0/U up to: 600V. Test voltage up to: 3,5 kV (5 minutes).
Maximum operation temperature of conductor is 105°C.
PVC insulated cables (with or without outer sheath) are used for indoor
electrical appliances. The cables are designed to pass through fixed,
heavy-duty, anti-leakage conduits in: fixed on/in the walls, ceillings
or floors, embedded in the walls, ceillings or floors and buried
underground.
Made in accordance to TCVN 6610-3 / IEC 60227-3; TCVN 6610-5 / IEC 60227-5;
TCVN 6612 / IEC 60228; JIS C 3307; JIS C 3102; AS/NZS 5000.1; AS/NZS 1125.